Skip to product information
$9,450.00
LIMIT CLIMATE CHANGE THROUGH ENERGY-EFFICIENT HEATING
The challenge for heat pumps has long been their efficiency in very cold weather.
The Unix central heat pump uses cutting-edge technology developed by GREE for
offer powerful heating capacity at outdoor temperatures as low as -30°C. Perfect
for our harsh Canadian winters!
- INSTALLATION FLEXIBILITY
A) Install a complete GREE kit, or
B) Upgrade with a third-party indoor unit or with a combination furnace and a cabinet
reel, to reduce labor and equipment costs.
- STANDARD 24V COMMUNICATION
The Unix series communication system is compatible with most standard 24V power supplies.
wired thermostats on the market.
| System performance | |
|---|---|
| Cooling capacity | 24,000 BTU/h (12,000 – 24,000) |
| Heating capacity | 24,000 BTU/h (12,000 – 30,000) |
| Power consumption (cooling) | 1920 W |
| Electricity consumption (heating) | 1670 W |
| SEER 2 | 17.0 BTU/W*h |
| HSPF 2 | 9.0 BTU/W*h |
| EER 2 | 12.0 BTU/W*h |
| COP | 4.20 W/W |
| Indoor unit specifications | |
| Dehumidification capacity | 2.85 (6.03) L/h (pt/h) |
| Airflow | 1,631 (960) m³/h (CFM) |
| Sound pressure level | 45 dB(A) |
| Dimensions | 540 x 1224 x 540 (21-1/4 x 48-1/4 x 21-1/4) mm (in) |
| Weight (net) | 71 (156.5) kg (lb) |
| Weight (gross) | 77 (169.8) kg (lb) |
| Outdoor unit specifications | |
| Ambient temperature range (cooling) | -15 to 54 (5 to 129) °C (°F) |
| Ambient temperature range (heating) | -30 to 24 (-22 to 75) °C (°F) |
| Sound pressure level | 52 (45 – 56) dB(A) |
| Dimensions | 820 x 940 x 460 (32-1/4 x 37 x 18-1/8) mm (in) |
| Weight (net) | 98.5 (217.2) kg (lb) |
| Weight (gross) | 109 (240.3) kg (lb) |